| EFRP-2462 | 460+460 watts Output power1+1 Redundant ConfigurationPS2 Mini Redundant PowerMeet 4U Rackmount Server SystemDimension: 150(W) x 86(H) x 190(D) mm |
| DownLoad | DRAWINGMTBFFCCULTUVCBBSMI |
Features : | | For AC 100V - 240V Full RangeActive Power Factor CorrectionHot Swappable DesignFront Panel LED to Indicate Power StatusRemote DC Sense on +5V and +3.3VPower Fault Alarm SignalsOver Voltage ProtectionOver Current ProtectionOver Power ProtectionShort Circuit ProtectionMTBF >100,000 Hours |
General Specifications : | | Input Range: 180 to 240 VAC, ±10%Power Factor: 0.95 minimumEfficiency: 65% minimum, at full loadHold up Time: 17mS minimum, at full loadPSON (Remote ON/OFF): TTL SignalPower Good: 100 to 500 ms, TTL SignalCooling Fan: 40x40x20 mmOperating Temperature: 0 to 40ºCOperating Humidity: 20 to 90% |
Regulation, Ripple & Noise: | | Output | +3.3V | +5V | +12V1 | +12V2 | +12V3 | +12V4- | -5V | -12V | +5Vsb | Load Regulation | ± 5% | ± 5% | ± 5% | - | - | - | - | ± 10% | ± 5% | Cross Regulation | ± 5% | ± 5% | ± 5% | - | - | - | - | ± 10% | ± 5% | Line Regulation | ± 1% | ± 1% | ± 1% | - | - | - | - | ± 1% | ± 1% | Ripple & Noise | 50mV | 50mV | 120mV | - | - | - | - | 120mV | 50mV |
|
Input and Output Ratings: | | Input | Output | Voltage | Frequency | Current | Watt | Load | +3.3V | +5V | +12V1 | +12V2 | +12V3 | +12V4 | -5V | -12V | +5Vsb | 100-240 VAC | 47-63 Hz | 5A | 460W | Max. Load | 25A | 25A | 30A | - | - | - | - | 0.8A | 2A | Min. Load | 1A | 1A | 2.5A | - | - | - | - | 0.1A | 0.1A |
| NOTE: The +5 & +3.3 Volt combined total output shall not exceed 150WThe +5, +3.3 and +12 Volt combined total output shall not exceed 440WNoise bandwidth is from DC to 20 MHz. |
Agency Requirements : | | Harmonic: Meet EN61000-3-2 standardsEMI/RFI: CE, FCC class B, BSMI and CISPR class BSafety: UL, cUL, CB, TUV, CCC |
Applications : | | RackmountServerIndustrial PC |
|